Micrologix 1500 Programming4/17/2021
It has two serial ports, Channel 0 (round-shaped, 8-pin, DIN connector) and Channel 1 (standard DB9 socket).The current software in the PLC makes use of the Modbus Slave mode at the Channel 1.I do not have the dedicated programming cable with round, DIN connector so I would like to program it using a standard DB9-DB9 cable.Now, the problem is - am I able to connect to the PLC using Channel 1 I know that there is a default comm parameters switch, but it only affects the Channel 0.
Is there a way to temporarily default the Channel 1 parameters as well Just for programming Or maybe I am able to connect to the PLC despite the fact that it is in the Modbus Slave mode on that port Or do I have to buy the dedicated cable and program the PLC using the Channel 0. ![]() Every engineer and technician who has worked on MicroLogix controllers since 1995 has at least one. English Section.3 Franais.19 Deutscher Abschnitt.35 Sezione in Italiano.51 Seccin en espaol.67 Seo em Portugus.83 Publication 1764-5.1. For More Information.4 Overview.5 Base Unit Description.6 Hazardous Location Considerations. Mounting the Controller. Wiring the Controller.13 Specifications. Micrologix 1500 Programming Trial Automation WiringMore information on proper wiring and Industrial Automation Wiring 1770-4.1. ATTENTION: Do not remove protective debris strips until after the base and all other equipment in the panel near the base is mounted and wiring is complete. Once wiring is complete, remove protective debris strips and install processor unit. The following ATTENTION statement applies to use in hazardous locations. An end cap terminator (catalog number 1769-ECR) must be used at the end of the group of IO modules attached to the MicroLogix 1500 Controller. The maximum extension of the latch is 15 mm (0.67 in.) in the open position. Place a flat-blade screwdriver in the DIN rail latch at the bottom of the base unit. Holding the base unit, pry downward on the latch until the latch locks in the open position. Mounting Template To install your base unit using mounting screws: 1. Remove the mounting template from the inside back cover of this document. The terminals will accept a 6.35mm (0.25 in.) wide spade (standard for 6 screw for up to 14 AWG) or a 4 mm (metric 4) fork terminal. Switching inductive loads without surge suppression can significantly reduce the lifetime of relay contacts or damage transistor outputs. An jeder Seite 50 mm Zwischenraum zur ausreichenden Lftung lassen, siehe Abbildung unten. Ulteriori informazioni.52 Generalit. Descrizioni relative allunit di base. Considerazioni sulle aree pericolose.55 Montaggio del controllore. Avere ulteriori informazioni sui modi Industrial Automation Wiring 1770-4.1. Per prevenire surriscaldamento rimuovere le strisce di protezione prima del funzionamento. Mais informaes sobre as tcnicas e Industrial Automation Wiring 1770-4.1.
0 Comments
Read More
Leave a Reply. |